The volumetric flow rate in the pipes.
Additional info
From ProcessLib/HeatTransportBHE/BHE/CreateFlowAndTemperatureControl.cpp line 354
- This is a required parameter.
- Data type:
std::string
- Expanded tag path: processes.process.HEAT_TRANSPORT_BHE.borehole_heat_exchangers.borehole_heat_exchanger.flow_and_temperature_control.InflowTemperature.flow_rate
- Go to source code: → ogs/ogs/6.5.8